ORIENTAL MOTOR U.S.A. Corp.
1001 Knox Street
Torrance, CA 90502
1-800-GO-VEXTA (468-3982)
 
        
| Motor Type | - Brushless DC Motor | 
| Motor Frame Size | - 4.09 in. | 
| Output Power | - 400 W (1/2 HP) | 
| Power Supply | - Single-Phase, Three-Phase 200-240 VAC | 
| Frequency | - 50 Hz60 Hz | 
| Rated Input Current | -
                                                                                          4.7 A (Single-Phase) 2.8 A (Three-Phase) | 
| Shaft/Gear Type | - Parallel Shaft Gearhead | 
| Gear Ratio (X:1) | - 30 :1 | 
| Output Shaft Diameter | - 22 mm | 
| Rated Torque | - 290 lb-in | 
| Electromagnetic Brake | - Equipped | 
| Brake Type | - Power off activated type, automatically controller by the driver | 
| Static Friction Torque | - 184 oz-in | 
| Variable Speed Range (r/min) | -
                                                                                          Digital setting: 0.07 ~ 133 r/min (2000:1) Analog setting: 1 ~ 133 r/min (133:1) | 
| Permissible Load Inertia | - 21000 oz-in² | 
| Permissible Overhung Load | -
                                                                                          0.39 in. from Shaft End = 123 0.79 in. from Shaft End = 180 lb | 
| Permissible Thrust Load | - 67 lb | 
| Max. Extension Length (m) | - Motor and driver distance: 99.7 ft. (30.4 m) | 
| Components | - GFS6G30 [Gearhead] BXSD400-C [Driver] BXM6400M-GFS [Motor] | 
| RoHS Compliant | - These products do not contain substances that exceed the regulation values in the RoHS Directive. | 
| Safety Standards | - UL CSA CE | 
| CE Marking | - Low Voltage Directives EMC Directives | 
| Insulation Resistance (Motor) | - 100 M Ω or more when 500 VDC megger is applied between the windings and the case after continuous operation under normal ambient temperature and humidity (except for encoder). | 
| Insulation Resistance (Driver) | - 100 M Ω or more when 500 VDC megger is applied between the power supply input terminal and the case, and between the power supply input terminal and the I/O terminal after continuous operation under normal ambient temperature and humidity. | 
| Dielectric Strength (Motor) | - Sufficient to withstand 1.5 kVAC at 50 Hz applied between the windings and the case for 1 minute after continuous operation under normal ambient temperature and humidity (except for encoder). | 
| Dielectric Strength (Driver) | - Sufficient to withstand 1.5 kVAC, 50 Hz applied between case and power supply input for 1 min. and 1.5 kVAC, 50 Hz applied between power supply input and the I/O terminal for 1 min. after continuous operation under normal ambient temperature and humidity. | 
| Temperature Rise (Motor) | - Temperature rise of the windings is 50°C (90°F) max. and that of the case surface is 40°C (72°F) max, measured by the thermocouple method after rated continuous operation under normal ambient temperature and humidity. | 
| Temperature Rise (Driver) | - Temperature rise of the heat sink is 50°C (90°F) max. measured by the thermocouple method after rated continuous operation under normal ambient temperature and humidity. [60°C (108°F) max. when drivers are installed in contact with each | 
| Ambient Temperature Range | -
                                                                                          [Motor] 32°F ~ 122°F (0°C ~ 50°C), nonfreezing [Driver] 32°F ~ 72°F (0°C ~ 40°C) when drivers are installed in contact with each other | 
| Ambient Humidity | - 85% max. (non-condensing) | 
| Operating Atmosphere | - No corrosive gases or dust. Cannot be used in a radioactive area, magnetic field, vacuum, or other special environments. | 
| Altitude | - Max of 10000 ft. (3000 m) above sea level | 
| Insulation Class | - UL/CSA Standards: 105 (A), EN Standards: 120 (E) | 
| Degree of Protection | -
                                                                                          IP54 (excluding connectors) [Motor] IP20 [Driver] | 
|  | - Speed Control Mode | 
| Speed Control Method (Select one of the following) | -
                                                                                          Digital Setting: 
 Analog Setting: 
 | 
| Acceleration/Deceleration Time | -
                                                                                          Digital Setting: 0.000 ~ 30.00 s (rated speed, no load) Analog Setting: 0.1 ~ 30 s (rated speed, no load) | 
| Acceleration/Deceleration Time Setting Method | -
                                                                                          Digital Setting: Select one of the following methods: (Individual settings) 
 Analog Setting: Common to operating Data No. 0 and No. 1 
 | 
| Operation Data Setting Number | - 16 Points | 
| Operation During Motor Standstill | -
                                                                                          Operations can be selected when the motor is at standstill 
 | 
| Other Operations | - JOG operation, test operation, teaching (excluding MEXE02) | 
|  | - Position Control Mode | 
| Travel Amount Setting Range | - -8,388,608 ~ +8,388,607 step | 
| Resolution | - 0.72° (500 steps/rotation) | 
| Operating Modes | - Incremental or absolute | 
| Operation Functions | - Independent, linked, linked 2, sequential, direct | 
| Positioning Accel/Decel Time | - 0.000 ~ 30.00 s (rated speed, no load) | 
| Positioning Operations | - Continous operation, JOG operation, return-to-home operation, test operation, teaching | 
|  | - Torque Control Mode | 
| Torque Limit Control | - The motor's output torque can be limited in speed control mode and position control mode. | 
| Torque Limiting Setting Range | - 0 ~ 250% | 
| Torque Limiting Setting Methods | -
                                                                                          Digital Setting: Select one of the following methods: 
 Analog Setting: 
 | 