ORIENTAL MOTOR U.S.A. Corp.
1001 Knox Street
Torrance, CA 90502
1-800-GO-VEXTA (468-3982)
Large airflow, high static pressure and high-efficient AC input axial fans.
| Items |
MRS16-BTA 6.30 in. (160 mm) Axial Fan, Single-Phase 100/110/115 VAC Web Price $184.00
|
MRS16-BTM 6.30 in. (160 mm) Axial Fan, Single-Phase 100/110/115 VAC Web Price $195.00
|
MRS16-BUL 6.30 in. (160 mm) Axial Fan, Single-Phase 100/110/115 VAC Web Price $104.00
|
MRS16-DTA 6.30 in. (160 mm) Axial Fan, Single-Phase 200/230 VAC Web Price $184.00
|
MRS16-DTM 6.30 in. (160 mm) Axial Fan, Single-Phase 200/230 VAC Web Price $200.00
|
|||||
| Frame Size | - 6.30 in | |||||||||
| Power Supply | - Single-Phase 110/115 VAC | - Single-Phase 110/115 VAC | - Single-Phase 110/115 VAC | - Single-Phase 220/230 VAC | - Single-Phase 220/230 VAC | |||||
| Frequency | - 50 Hz60 Hz | |||||||||
| Current | - 0.46 A [100 VAC, 60 Hz] 0.47 A [100 VAC, 50 Hz] 0.48 A [110 VAC, 60 Hz] 0.49 A [115 VAC, 60 Hz] | - 0.46 A [100 VAC, 60 Hz] 0.47 A [100 VAC, 50 Hz] 0.48 A [110 VAC, 60 Hz] 0.49 A [115 VAC, 60 Hz] | - 0.46 A [100 VAC, 60 Hz] 0.47 A [100 VAC, 50 Hz] 0.48 A [110 VAC, 60 Hz] 0.49 A [115 VAC, 60 Hz] | - 0.24 A [200 VAC, 50/60 Hz] 0.25 A [230 VAC, 60 Hz] | - 0.24 A [200 VAC, 50/60 Hz] 0.25 A [230 VAC, 60 Hz] | |||||
| Function | - Low Speed Alarm - Contact: OFF | - Low Speed Alarm - Electronic | - None | - Low Speed Alarm - Contact: OFF | - Low Speed Alarm - Electronic | |||||
| Connection Type | - Terminal Box | |||||||||
| Speed (r/min) |
-
2800 [100 VAC, 50 Hz] 3250 [100 VAC, 60 Hz] 3300 [110/115 VAC, 60 Hz] |
-
2800 [100 VAC, 50 Hz] 3250 [100 VAC, 60 Hz] 3300 [110/115 VAC, 60 Hz] |
-
2800 [100 VAC, 50 Hz] 3250 [100 VAC, 60 Hz] 3300 [110/115 VAC, 60 Hz] |
-
2800 [200 VAC, 50 Hz] 3250 [200 VAC, 60 Hz] 3300 [230 VAC, 60 Hz] |
-
2800 [200 VAC, 50 Hz] 3250 [200 VAC, 60 Hz] 3300 [230 VAC, 60 Hz] |
|||||
| Max. Air Flow |
-
219 CFM [100 VAC, 50 Hz] 258 CFM [100/110/115 VAC, 60 Hz] |
-
219 CFM [100 VAC, 50 Hz] 258 CFM [100/110/115 VAC, 60 Hz] |
-
219 CFM [100 VAC, 50 Hz] 258 CFM [100/110/115 VAC, 60 Hz] |
-
219 CFM [200 VAC, 50 Hz] 258 CFM [200/230 VAC, 60 Hz] |
-
219 CFM [200 VAC, 50 Hz] 258 CFM [200/230 VAC, 60 Hz] |
|||||
| Max. Static Pressure |
-
0.509 inH2O [100 VAC, 50 Hz] 0.63 inH2O [100/110/115 VAC, 60 Hz] |
-
0.509 inH2O [100 VAC, 50 Hz] 0.63 inH2O [100/110/115 VAC, 60 Hz] |
-
0.509 inH2O [100 VAC, 50 Hz] 0.63 inH2O [100/110/115 VAC, 60 Hz] |
-
0.509 inH2O [200 VAC, 50 Hz] 0.63 inH2O [200/230 VAC, 60 Hz] |
-
0.509 inH2O [200 VAC, 50 Hz] 0.63 inH2O [200/230 VAC, 60 Hz] |
|||||
| Noise Level |
-
49 dB (A) [100 VAC, 50 Hz] 52 dB (A) [100 VAC, 60 Hz] 53 dB (A) [110/115 VAC, 60 Hz] |
-
49 dB (A) [100 VAC, 50 Hz] 52 dB (A) [100 VAC, 60 Hz] 53 dB (A) [110/115 VAC, 60 Hz] |
-
49 dB (A) [100 VAC, 50 Hz] 52 dB (A) [100 VAC, 60 Hz] 53 dB (A) [110/115 VAC, 60 Hz] |
-
49 dB (A) [200 VAC, 50 Hz] 52 dB (A) [200 VAC, 60 Hz] 53 dB (A) [230 VAC, 60 Hz] |
-
49 dB (A) [200 VAC, 50 Hz] 52 dB (A) [200 VAC, 60 Hz] 53 dB (A) [230 VAC, 60 Hz] |
|||||
| Fan Kit | - Fan Only | |||||||||
| Safety Standards | - UL CSA EN CE | |||||||||
|
|
||||||||||