CAD / Búsqueda Manual
Para encontrar CAD y Manuales de Operador de nuestros products, por favor realice la búsqueda usando el número de item

Para Inglés o Español:
Para japonés:

Clientes de Mexíco:
Servicio Al Cliente - +001-847-871-5931
Soporte técnico - 01-800-681-5309
Clientes Internacionales:
+1-847-871-5931 o
+1-310-715-3304
Para soporte en productos del catálogo japonés:
1-800-746-6872 o
+1-310-715-3304
El contenido a continuación está en inglés
- Right-mounted motor

Product Line |
- ORIX ® |
Fan Type |
- Cross Flow |
Frame Size |
- 3.54 in90 mm |
Impeller Length |
- 11.81 in.300 mm |
Motor Mount |
- Right |
Power Supply |
- Single-Phase 200/220/230 VAC |
Frequency |
- 50 Hz60 Hz |
Current |
- 0.2 A [200/230 VAC, 50 Hz] 0.25 A [200/220/230 VAC, 60 Hz] |
Speed (r/min) |
-
2500 [200 VAC, 50 Hz] 2700 [200 VAC, 60 Hz] 2700 [230 VAC, 50 Hz] 2950 [220 VAC, 60 Hz] 3000 [230 VAC, 60 Hz] |
Max. Air Flow |
-
212 CFM [200 VAC, 50 Hz] 219 CFM [200 VAC, 60 Hz] 219 CFM [230 VAC, 50 Hz] 233 CFM [220 VAC, 60 Hz] 240 CFM [230 VAC, 60 Hz] 6.0 m3/min [200 VAC, 50 Hz] 6.2 m3/min [200 VAC, 60 Hz] 6.2 m3/min [230 VAC, 50 Hz] 6.6 m3/min [220 VAC, 60 Hz] 6.8 m3/min [230 VAC, 60 Hz] |
Max. Static Pressure |
-
0.297 inH2O [200 VAC, 50 Hz] 0.313 inH2O [230 VAC, 50 Hz] 0.413 inH2O [200 VAC, 60 Hz] 0.425 inH2O [220/230 VAC, 60 Hz] 74 Pa [200 VAC, 50 Hz] 78 Pa [230 VAC, 50 Hz] 103 Pa [200 VAC, 60 Hz] 106 Pa [220/230 VAC, 60 Hz] |
Noise Level |
-
58 dB (A) [200 VAC, 50 Hz] 60 dB (A) [200 VAC, 60 Hz] 60 dB (A) [230 VAC, 50 Hz] 62 dB (A) [220 VAC, 60 Hz], 63 dB (A) [230 VAC, 60 Hz] |
RoHS Compliant |
- Yes |
Safety Standards |
- UL CSA EN CE |
CE Marking |
- Low Voltage Directives |
Insulation Resistance |
- 100 M Ω or more when 500 VDC is applied between the windings and the frame under normal ambient temperature and humidity. |
Dielectric Strength |
- Sufficient to withstand 1.5 kV at 50Hz applied between the windings and the frame for 1 minute under normal ambient temperature and humidity. |
Temperature Rise |
- 81°F (45°C) or less measured by the thermometer method after the temperature of the motor case has stabilized after continuous operation under normal ambient temperature and humidity. |
Insulation Class |
- Class E (248°F [120°C]), Recognized as Class A (221°F [105°C]) by UL and CSA standards. |
Overheat Protection |
-
Built-in thermal protector (automatic reset type) Operating temperature, open: 248°F±9°F (120°C±5°C), close: 170.6°F±27°F (77°C±15°C) |
Ambient Temperature Range |
- 14°F ~ 140°F (-10°C ~ 60°C) |
Ambient Humidity |
- 85% or less (noncondensing) |
|
|
|