El contenido a continuación está en inglés

Cross Flow fans employ a specifically designed blade to create parallel air movement that reaches even distant objects in a wide, uniform pattern. These fans provide right-angle airflow and rectangular shape, allowing for installation in corners and space savings in applications such as circuit board cooling and air curtains.
  • Right-mounted motor

 

Unit of Measure

Product Line

- ORIX ®

Fan Type

- Cross Flow

Frame Size

- 3.54 in90 mm

Impeller Length

- 11.81 in.300 mm

Motor Mount

- Right

Power Supply

- Single-Phase 200/220/230 VAC

Frequency

- 50 Hz60 Hz

Current

- 0.2 A [200/230 VAC, 50 Hz] 0.25 A [200/220/230 VAC, 60 Hz]

Speed (r/min)

- 2500 [200 VAC, 50 Hz]
2700 [200 VAC, 60 Hz]
2700 [230 VAC, 50 Hz]
2950 [220 VAC, 60 Hz]
3000 [230 VAC, 60 Hz]

Max. Air Flow

- 212 CFM [200 VAC, 50 Hz]
219 CFM [200 VAC, 60 Hz]
219 CFM [230 VAC, 50 Hz]
233 CFM [220 VAC, 60 Hz]
240 CFM [230 VAC, 60 Hz]  
6.0 m3/min [200 VAC, 50 Hz]
6.2 m3/min [200 VAC, 60 Hz]
6.2 m3/min [230 VAC, 50 Hz]
6.6 m3/min [220 VAC, 60 Hz]
6.8 m3/min [230 VAC, 60 Hz]  

Max. Static Pressure

- 0.297 inH2O [200 VAC, 50 Hz]
0.313 inH2O [230 VAC, 50 Hz]
0.413 inH2O [200 VAC, 60 Hz]
0.425 inH2O [220/230 VAC, 60 Hz]  
74 Pa [200 VAC, 50 Hz]
78 Pa [230 VAC, 50 Hz]
103 Pa [200 VAC, 60 Hz]
106 Pa [220/230 VAC, 60 Hz]  

Noise Level

- 58 dB (A) [200 VAC, 50 Hz]
60 dB (A) [200 VAC, 60 Hz]
60 dB (A) [230 VAC, 50 Hz]
62 dB (A) [220 VAC, 60 Hz], 63 dB (A) [230 VAC, 60 Hz]

RoHS Compliant

- Yes

Safety Standards

- UL CSA EN CE

CE Marking

- Low Voltage Directives

Insulation Resistance

- 100 M Ω or more when 500 VDC is applied between the windings and the frame under normal ambient temperature and humidity.

Dielectric Strength

- Sufficient to withstand 1.5 kV at 50Hz applied between the windings and the frame for 1 minute under normal ambient temperature and humidity.

Temperature Rise

- 81°F (45°C) or less measured by the thermometer method after the temperature of the motor case has stabilized after continuous operation under normal ambient temperature and humidity.

Insulation Class

- Class E (248°F [120°C]), Recognized as Class A (221°F [105°C]) by UL and CSA standards.

Overheat Protection

- Built-in thermal protector (automatic reset type)
Operating temperature, open: 248°F±9°F (120°C±5°C), close: 170.6°F±27°F (77°C±15°C)

Ambient Temperature Range

- 14°F ~ 140°F (-10°C ~ 60°C)

Ambient Humidity

- 85% or less (noncondensing)


 


 


 


 

©2017 - ORIENTAL MOTOR USA CORP. - Todos los Derechos Reservados