El contenido a continuación está en inglés

Cross Flow fans employ a specifically designed blade to create parallel air movement that reaches even distant objects in a wide, uniform pattern. These fans provide right-angle airflow and rectangular shape, allowing for installation in corners and space savings in applications such as circuit board cooling and air curtains.
  • Left-mounted motor

 

Unit of Measure

Product Line

- ORIX ®

Fan Type

- Cross Flow

Frame Size

- 3.54 in90 mm

Impeller Length

- 5.91 in.150 mm

Motor Mount

- Left

Power Supply

- Single-Phase 200/220/230 VAC

Frequency

- 50 Hz60 Hz

Current

- 0.2 A [200/230 VAC, 50 Hz] 0.25 A [200/220/230 VAC, 60 Hz]

Speed (r/min)

- 2650 [200 VAC, 50 Hz]
2800 [230 VAC, 50 Hz]
2950 [200 VAC, 60 Hz]
3200 [220 VAC, 60 Hz]
3250 [230 VAC, 60 Hz]

Max. Air Flow

- 120 CFM [200 VAC, 50 Hz]
127 CFM [230 VAC, 50 Hz]
131 CFM [200 VAC, 60 Hz]
141 CFM [220 VAC, 60 Hz]
145 CFM [230 VAC, 60 Hz]  
3.4 m3/min [200 VAC, 50 Hz]
3.6 m3/min [230 VAC, 50 Hz]
3.7 m3/min [200 VAC, 60 Hz]
4.0 m3/min [220 VAC, 60 Hz]
4.1 m3/min [230 VAC, 60 Hz]  

Max. Static Pressure

- 0.353 inH2O [200 VAC, 50 Hz]
0.369 inH2O [230 VAC, 50 Hz]
0.509 inH2O [200 VAC, 60 Hz]
0.529 inH2O [220/230 VAC, 60 Hz]  
88 Pa [200 VAC, 50 Hz]
92 Pa [230 VAC, 50 Hz]
127 Pa [200 VAC, 60 Hz]
132 Pa [220/230 VAC, 60 Hz]  

Noise Level

- 60 dB (A) [200 VAC, 50 Hz]
61 dB (A) [230 VAC, 50 Hz]
63 dB (A) [200 VAC, 60 Hz]
64 dB (A) [220/230VAC, 60 Hz]

RoHS Compliant

- Yes

Safety Standards

- UL CSA EN CE

CE Marking

- Low Voltage Directives

Insulation Resistance

- 100 M Ω or more when 500 VDC is applied between the windings and the frame under normal ambient temperature and humidity.

Dielectric Strength

- Sufficient to withstand 1.5 kV at 50Hz applied between the windings and the frame for 1 minute under normal ambient temperature and humidity.

Temperature Rise

- 81°F (45°C) or less measured by the thermometer method after the temperature of the motor case has stabilized after continuous operation under normal ambient temperature and humidity.

Insulation Class

- Class E (248°F [120°C]), Recognized as Class A (221°F [105°C]) by UL and CSA standards.

Overheat Protection

- Built-in thermal protector (automatic reset type)
Operating temperature, open: 248°F±9°F (120°C±5°C), close: 170.6°F±27°F (77°C±15°C)

Ambient Temperature Range

- 14°F ~ 140°F (-10°C ~ 60°C)

Ambient Humidity

- 85% or less (noncondensing)


 


 


 


 

©2017 - ORIENTAL MOTOR USA CORP. - Todos los Derechos Reservados