Centrifugal fans / blowers maximize static pressure to provide concentrated airflow in one defined direction. These blowers can be used in a fixed position or mounted on moving parts, and are optimal for local cooling and airflow through ducts.
  • Fan kit features centrifugal blower, mounting bracket and mounting screws in a single package

Fan Kit

 

Unit of Measure

Fan Type

- Centrifugal Blower

Impeller Diameter

- 1.97 in.50 mm

Power Supply

- Single-Phase 100/110/115 VAC

Current (A)

- 0.11 [100 VAC, 50 Hz, 110/115 VAC, 60 Hz]
0.10 [100 VAC, 60 Hz]

Speed (r/min)

- 2600 [100 VAC, 50 Hz]
3000 [100 VAC, 60 Hz]
3200 [110/115 VAC, 60 Hz]

Max. Air Flow

- 7.41 CFM [100 VAC, 50 Hz]
8.47 CFM [100 VAC, 60 Hz]
8.83 CFM [110/115 VAC, 60 Hz]  
0.21 m3/min [100 VAC, 50 Hz]
0.24 m3/min [100 VAC, 60 Hz]
0.25 m3/min [110/115 VAC, 60 Hz]  

Max. Static Pressure

- 0.149 inH2O [100 VAC, 50 Hz]
0.213 inH2O [100 VAC, 60 Hz]
0.221 inH2O [110/115 VAC, 60 Hz]  
37 Pa [100 VAC, 50 Hz]
53 Pa [100 VAC, 60 Hz]
55 Pa [110/115 VAC, 60 Hz]  

Noise Level

- 33 dB (A) [100 VAC, 50 Hz]
37 dB (A) [100 VAC, 60 Hz]
38 dB (A) [110/115 VAC, 60 Hz]

Components

- MB520-B (Fan Unit)
PAS2B (Mounting Bracket)
M4 x 10 mm (0.39 in.) (Mounting Screws)

Fan Kit

- Fan, Mounting Bracket, Mounting Screws

RoHS Compliant

- Yes

Safety Standards

- UL CSA EN CE

CE Marking

- Low Voltage Directives

Insulation Resistance

- 100 M Ω or more when 500 VDC is applied between the windings and the frame under normal ambient temperature and humidity.

Dielectric Strength

- Sufficient to withstand 1.5 kV at 50Hz applied between the windings and the frame for 1 minute under normal ambient temperature and humidity.

Temperature Rise

- 81°F (45°C) or less measured by the thermometer method after the temperature of the motor case has stabilized after continuous operation under normal ambient temperature and humidity.

Insulation Class

- Class E (248°F [120°C]), Recognized as Class A (221°F [105°C]) by UL and CSA standards.

Overheat Protection

- Impedance protection

Ambient Temperature Range

- 14°F ~ 140°F (-10°C ~ 60°C)

Ambient Humidity

- 85% or less (noncondensing)

List Price

- $50.00


 


 


 