- Fan kit features centrifugal blower, mounting bracket, filter and mounting screws in a single package.

Fan Kits
Fan Type |
- Centrifugal Blower |
Impeller Diameter |
- 3.94 in.100 mm |
Power Supply |
- Single-Phase 100/110/115 VAC |
Current (A) |
-
0.50 [100 VAC, 50 Hz] 0.55 [100/110/115 VAC, 60 Hz] |
Speed (r/min) |
-
2750 [100 VAC, 50 Hz] 3050 [100 VAC, 60 Hz] 3200 [110/115 VAC, 60 Hz] |
Max. Air Flow |
-
81.2 CFM [100 VAC, 50 Hz] 91.8 CFM [100/110/115 VAC, 60 Hz] 2.3 m3/min [100 VAC, 50 Hz] 2.6 m3/min [100/110/115 VAC, 60 Hz] |
Max. Static Pressure |
-
0.826 inH2O [100 VAC, 50 Hz] 1.14 inH2O [100/110/115 VAC, 60 Hz] 206 Pa [100 VAC, 50 Hz] 284 Pa [100/110/115 VAC, 60 Hz] |
Noise Level |
-
60 dB (A) [100 VAC, 50 Hz] 63 dB (A) [100 VAC, 60 Hz] 64 dB (A) [110/115 VAC, 60 Hz] |
Components |
-
MB1040-B (Fan Unit) PAS4B (Mounting Bracket) FLB10 (Filter) M5 x 20 mm (0.79 in.) (Mounting Screws) |
Fan Kit |
- Fan, Filter, Mounting Bracket, Mounting Screws |
RoHS Compliant |
- Yes |
Safety Standards |
- UL CSA EN CE |
CE Marking |
- Low Voltage Directives |
Insulation Resistance |
- 100 M Ω or more when 500 VDC is applied between the windings and the frame under normal ambient temperature and humidity. |
Dielectric Strength |
- Sufficient to withstand 1.5 kV at 50Hz applied between the windings and the frame for 1 minute under normal ambient temperature and humidity. |
Temperature Rise |
- 81°F (45°C) or less measured by the thermometer method after the temperature of the motor case has stabilized after continuous operation under normal ambient temperature and humidity. |
Insulation Class |
- Class E (248°F [120°C]), Recognized as Class A (221°F [105°C]) by UL and CSA standards. |
Overheat Protection |
- Operating temperature, open: 248°F±9°F (120°C±5°C), close: 170.6°F±27°F (77°C±15°C) Built-in thermal protector (automatic reset type) |
Ambient Temperature Range |
- 14°F ~ 122°F (-10°C ~ 50°C) |
Ambient Humidity |
- 85% or less (noncondensing) |
|
|